Página 2

017-220-J0 Rev B82. General Description2.1 OverviewFigure 1 — Alpha Micro SecureBatteriesBattery breakerInput circuit breakerRS232 connector,

Página 3

9017-220-J0 Rev BFigure 2 — Output Connectors and Monitoring LEDsThe Alpha Micro Secure has a bar with monitoring LEDs, an RS-232 connector and

Página 4 - Table of Contents

017-220-J0 Rev B103. Site PlanningWARNING!The Alpha Micro Secure must be installed in a restricted area accessible only by quali-ed service pers

Página 5 - List of Figures

11017-220-J0 Rev B4. Unpacking the Alpha Micro SecureFollow these guidelines for unpacking the Alpha Micro Secure.WARNING!The Alpha Micro Secure

Página 6

017-220-J0 Rev B125. InstallationOnce the installation location has been planned and prepared, you are ready to install the Alpha Micro Secure. T

Página 7 - 1. Safety

13017-220-J0 Rev B5.2.1 Mounting to a WallThe Alpha Micro Secure can be mounted to a wall or to wall studs. The wall or studs should be able to h

Página 8

017-220-J0 Rev B145.2.2 Mounting to a Wooden PoleThe Alpha Micro Secure can be pole mounted with the optional mounting bracket (Alpha Kit# 740-75

Página 9

15017-220-J0 Rev B5.2.3 Mounting to a steel or concrete poleTo strap mount the Alpha Micro Secure to the pole you need the optional mounting brac

Página 10 - 2. General Description

017-220-J0 Rev B165.3 Wiring the Alpha Micro Secure5.3.1 Tools and Materials Required• Slotted-tip screwdrivers for tightening screws on termin

Página 11 - Bottom View

17017-220-J0 Rev BFigure 7 — Battery Locations and Wiring5.4 Installing and Wiring the BatteriesWARNING!Before proceeding, verify the line wire

Página 13 - Table A — Standard Items

017-220-J0 Rev B185.5 Powering Up the Alpha Micro SecureMake sure that the Line power is qualified but turned off and the batteries are fully char

Página 14 - 5. Installation

19017-220-J0 Rev B6. OperationThe following subsections describe the operation of the Alpha Micro Secure:• Communicating with the Alpha Micro S

Página 15 - 12.0in (30.5cm)

017-220-J0 Rev B206.1 Communicating with the Alpha Micro SecureThere are several ways you can communicate with the Alpha Micro Secure UPS:1. Usi

Página 16 - Procedure

21017-220-J0 Rev B6.2 Communicating with the RS-232 interface6.2.1 Wiring the RS-232 portThe Alpha Micro Secure’s front panel has a DE-9 female

Página 17

017-220-J0 Rev B226.3 Using the Main MenuThe Alpha Micro Secure main menu screen runs on a command line system. This program does not recognize t

Página 18

23017-220-J0 Rev B6.4 RS-232 Menu TreeSubmenus #1, 2 and 4 are read-only screens for monitoring the Alpha Micro Secure To control the Alpha Micro

Página 19

017-220-J0 Rev B24Table D — Line StatusNormalThe line is within specifications. See specifications, “Boost/Buck/Line Transfer Thresholds”. The Alp

Página 20

25017-220-J0 Rev B6.4.3 Fault and Alarm DisplaysFault and alarm displays any malfunctions the Alpha Micro Secure has encountered. Also see "

Página 21 - 6. Operation

017-220-J0 Rev B266.4.4 Adjusting and Controlling the Alpha Micro SecureThe Maintenance submenu lets you control the Alpha Micro Secure and chang

Página 22 - 1 & 2

27017-220-J0 Rev B6.4.5 Programming the Dry Contacts and the ClockOn the Alpha Micro Secure front panel. contacts (C1 to C6) can be programmed to

Página 23 - 6.2.1 Wiring the RS-232 port

Alpha Micro Secure UPSInstallation and Operation ManualFor technical support, contact Alpha Technologies:Canada and USA: 1-888-462-7487International:

Página 24 - 6.3 Using the Main Menu

017-220-J0 Rev B286.4.6 Setting the Timer ContactThe front panel’s timer contact can be programmed to suit your application. See "Contacts C

Página 25 - 6.4 RS-232 Menu Tree

29017-220-J0 Rev B6.4.7 Setting the Date and TimeTable K — Setting the Date and TimeEnter command UPS display Descriptionclock and press Enter

Página 26 - 6.4.2 Output Status

017-220-J0 Rev B306.4.8 Viewing the Serial NumberTo display the serial number of the Alpha Micro Secure UPS, type "∗QY0" at the command

Página 27 - Table G — Alarms

31017-220-J0 Rev B6.4.10 100-Event LogUp to 100 events are stored in the Alpha Micro Secure’s log. If more than 100 events occur, the oldest is o

Página 28

017-220-J0 Rev B326.4.11 Communicating with the Alpha UPS MonitorIntroductionThe Alpha UPS Monitor graphical user interface (GUI) provides web or

Página 29 - Programming the Dry Contacts

33017-220-J0 Rev B6.4.12 Checking Your Windows Computer for the .NET Framework1. Click on the Start button.2. Go to and click on Settings.3. C

Página 30 - 017-220-J0 Rev B

017-220-J0 Rev B346.4.13 Installation and Set UpThe following tools and materials are required:• Alpha UPS Monitor, available for download from

Página 31

35017-220-J0 Rev B6.5 OperationThe various screens are described on the following pages and operate like Web or Windows-type screens. Point and c

Página 32

017-220-J0 Rev B366.5.2 UPS MonitoringThese read-only screens show the Alpha Micro Secure’s current input and output values and other measure-men

Página 33 - Self Test

37017-220-J0 Rev BRelay & Load ShedShows how the front panel dry contacts are configured. If any relays are used for load shedding, the time se

Página 34 - Introduction

017-220-J0 Rev B2Table of Contents1. Safety ...

Página 35

017-220-J0 Rev B386.5.3 UPS MaintenanceThe UPS Maintenance screens are used to configure and adjust the Alpha Micro Secure to meet your operating

Página 36

39017-220-J0 Rev BAn accurate battery runtime estimation requires the following parameter to be adjusted:• Peukert Number: Refer to the appendix

Página 37 - 6.5 Operation

017-220-J0 Rev B40Figure 22 — UPS Maintenance: Relay & Load Shed screenControlling the external fan by temperature triggered dry contactThe

Página 38 - Battery & Inverter

41017-220-J0 Rev BDry contact functions are not programmable through the LCD. Use the RS-232 GUI or the HyperTerminal instead.2. RS-232 GUI – Fig

Página 39 - User Input Status

017-220-J0 Rev B423. RS-232 HyperTerminal – the Temperature trigger function can be assigned to any available dry contacts as described in "

Página 40 - Unit Configuration

43017-220-J0 Rev BA typical application of this timer controlled dry contact function is to control a traffic light. When the grid power fails, the

Página 41 - Inverter

017-220-J0 Rev B44Figure 28 — Time Of Day Action StatusOnce the Time of Day Action is configured, the Alpha Micro Secure will automatically disab

Página 42 - RELAY TEMP

45017-220-J0 Rev BPasswordIs used to set the Alpha Micro Secure’s password. The factory set password is 1111.Figure 30 — UPS Maintenance: Passwor

Página 43

017-220-J0 Rev B46Figure 32 — User Input Configuration: Setting the Trigger TypeFigure 33 — User Input Configuration: Setting the Logic LevelF

Página 44 - Microprocessor

47017-220-J0 Rev BFigure 35 — User Input Current StatusFigure 36 — User Input Current StatusPerform a quick test by shorting the User Input 1 d

Página 45

3017-220-J0 Rev B10. Peukert Number and Battery Capacity ...7110.1 Intr

Página 46 - Time & Date

017-220-J0 Rev B48OperationMany of the screens used for Ethernet communications look and function the same and contain the same infor-mation as th

Página 47 - User Input

49017-220-J0 Rev BThe default command can be issued via the RS-232 HyperTerminal or the RS-232 GUI as follows:• RS-232 HyperTerminal – type defau

Página 48

017-220-J0 Rev B50Table M — List of ParametersMaximum battery charging currentTemperature compensation of battery charging Maximum allowable dur

Página 49

51017-220-J0 Rev BEvent HistoryThis screen shows the last 100 events recorded by the Alpha Micro Secure Choosing a number in the Event Index drop-

Página 50 - Operation

017-220-J0 Rev B52To view all the events, click on the View All button to open the Event Log Monitor window. Clicking on the Clear History button

Página 51 - CAUTION!

53017-220-J0 Rev BUpgrade FilesThis feature is available only on Alpha Micro Secure UPS equipped with the network interface card factory option.To

Página 52

017-220-J0 Rev B54Keep AliveThe Keep Alive feature can be used to reset power when a communication failure is detected. The purpose of the reset i

Página 53 - Alarms & Faults

55017-220-J0 Rev BKeep Alive status/manual control:a. The Status field allows the user to enable or disable the Keep Alive function. When disabled

Página 54

017-220-J0 Rev B56CAUTION!To successfully complete this procedure, you should have a working knowledge of network protocols and how to congure th

Página 55 - Communications

57017-220-J0 Rev B6.6.3 Types of TriggerThere are 3 types of trigger:Edge triggerWhen the user input changes from one state to the other, the Alp

Página 56 - Keep Alive

017-220-J0 Rev B4Figure 22 — UPS Maintenance: Relay & Load Shed screen... 40Figure 23 — Te

Página 57

017-220-J0 Rev B58Level AlternativeWhen the level is set to High, the Alpha Micro Secure is triggered to perform the next action when the user inp

Página 58

59017-220-J0 Rev B7. Maintenance7.1 Updating the Micro Secure Firmware (with Communication Module)If your Alpha Micro Secure is provided with th

Página 59 - 6.6.3 Types of Trigger

017-220-J0 Rev B60To upgrade the FXM firmware, browse to the .fbin or .bin file and click Send File to start the upload. This may take a few minutes

Página 60 - Action #2 Action #1

61017-220-J0 Rev B4. Connect the DB-9 to DB-9 cable between the Micro Secure and the laptop.5. Install the battery fuse.6. Start the FXMProgram

Página 61 - 7. Maintenance

017-220-J0 Rev B629. Click on Apply the update to the FXM unit.10. Watch the progress bar and the Programming Messages window. (If there is a co

Página 62 - Before Upgrading

63017-220-J0 Rev B7.3 Testing and Replacing the Batteries7.3.1 Battery lifeBatteries lose their ability to store power as they age. Regularly te

Página 63

017-220-J0 Rev B647.3.3 Battery MaintenanceThe batteries supplied with this unit are sealed and maintenance free. Regularly ensure that all conne

Página 64

65017-220-J0 Rev BWARNING!Read and understand the battery safety instructions in “Product Safety Information”.CAUTION!Make sure all the replacemen

Página 65 - Discharge Time

017-220-J0 Rev B667.4 Preventative MaintenancePerform preventative maintenance on the Alpha Micro Secure module every 6 to 12 months. For mission

Página 66 - Tools and Materials Required

67017-220-J0 Rev B8. TroubleshootingTable O — Troubleshooting GuideSymptom Action No output powerIs utility power connected?Is the battery brea

Página 67

5017-220-J0 Rev B1. SafetySAVE THESE INSTRUCTIONS: This manual contains important safety instructions that must be followed during the installati

Página 68 - 7.4 Preventative Maintenance

017-220-J0 Rev B68Table P — Mechanical SpecicationsParameter ValueDimensions H x W x D mm (in) Std: 15 (381) x 12 (305) x 6 (153)Weight without

Página 69 - 8. Troubleshooting

69017-220-J0 Rev BTable Q — Electrical SpecicationsParameter ValueInputVoltage (nominal), Vac120 or 230 (optional 220).Frequency, Hz, ±5%60/50

Página 70 - 9. Specifications

017-220-J0 Rev B70Table R — RegulatoryParameter ValueElectrical SafetyUL 1778, CSA 107.1, EN 50091-1-2, EN60950.EmissionFCC Part 15, Subpart B,

Página 71 - Parameter Value

71017-220-J0 Rev B10. Peukert Number and Battery Capacity10.1 IntroductionThe Alpha Micro Secure series UPS units run on batteries when the AC u

Página 72 - Radio Frequencies

017-220-J0 Rev B7210.4 ExampleThe following example shows how to calculate Peukert number and capacity from a configured battery string.Consider f

Página 73 - 10.1 Introduction

73017-220-J0 Rev B10.5 Using the SpreadsheetDownload the spreadsheet “Peukert’s Parameters Calculator.xls” from www.alpha.ca website. Enter the B

Página 74 - 10.4 Example

017-220-J0 Rev B7411. WarrantyAlpha Technologies Ltd. warrants all equipment manufactured by it to be free from defects in parts and labor, for a

Página 75 - 10.5 Using the Spreadsheet

75017-220-J0 Rev BComplete the following for your records:Serial # Options Purchase Date This unit was purchased from:Deal

Página 78

017-220-J0 Rev B61.2 General Warnings and CautionsYou must read and understand the following warnings before installing the Alpha Micro Secure an

Página 79

Visit us at www.alpha.ca Due to continuing product development, Alpha Technologies reserves the right to change specifications without notice. Copyrig

Página 80 - Visit us at www.alpha.ca

7017-220-J0 Rev B• Never let live battery wires touch the Alpha Micro Secure the enclosure or any other metal objects. This can cause a fire or ex